Testing PCB ground plane myths

(Electronics)

Basically everyone agrees that a ground plane provides a low inductance and low resistance return path for current, and prevents crosstalk/coupling between traces.

A ground plane does this by providing a return path1 for current that is physically close to the trace. Inductance and inductive coupling depend of the area of the loop formed, which minimized by a ground plane. With capacitive coupling, the ground plane “shorts” the electric field between traces, minimizing mutual capacitance.

After these basic points, everyone starts disagreeing. Some people say that a ground plane should be on both sides of the board, while others say just one. Some say that it should be split between different areas of the circuit, and others say this makes things worse. Some say that you should place a shield trace between fast signals, others say you should not.

So to test some of these claims, I designed a (1.6 mm thick) board with pairs of 15 mm traces and 2 mm of clearance between them. Both for capacitive and inductive coupling, long, parallel and nearby tracks are the worst case. Each end of the traces has a pin, and if a ground plane was present, a ground pin was placed by the trace pins to keep the return path as close as possible:

The layout of the PCB I used

One pair has no ground plane, another just a basic one on the back, and the rest have variations on ground planes:

I ran tests with a 50 MHz sine wave (10ns rise/fall times), which should be representative of a typical hobby project, but does not represent what happens in the microwave range. (The wavelength used is much larger then the traces)

Capacitive coupling

To measure capacitive coupling, I connected a function generator set to a 5v 50 MHz sine to one end of one trace, and a scope to the other end of the other trace. For tests with a ground plane, I removed the stock ground lead of the scope probe, and used a short (<2cm) length of wire from the probe’s ground ring to the ground pane. For the tests without one, I just clipped the scope’s ground clip to the function generator’s ground lead.

Capacitive coupling test setup

The scope probe has ~10 pF of capacitance to ground, around twice that of a 74HC gate input. These measurements are only accurate to around 5%, so pay no attention to single milivolt differences.

Coupled peak-to-peak voltage into 10 pF (More is worse)Configuration
800 mVNo ground plane, ground provided by 15 cm scope ground clip.
340 mVStandard ground plane.
352 mV2Split ground between traces
360 mVTraces over split
351 mVStandard ground with trace cutting across the ground plane crossing the tested traces
340 mVStandard ground with trace cutting across the ground plane along the tested traces
294 mVDouble sided ground
300 mVDouble sided ground + via stitching
88 mVDouble sided ground + shield trace3
48 mVDouble sided ground + shield trace3 + via stitching

A ground plane reduced capacitive coupling by more then 2 times, even in this worst case layout. Splitting the ground plane, often recommended between power supply, digital and analog sections increased coupling. A double sided ground only improved things if both sides were connected with vias right next to the trace, and worked much better if a grounded shield trace was placed between the two traces. (more than 16 times better then no ground plane!)

At least at this much-smaller-then-a-wavelength scale, a short trace under the ground plane has a fairly small effect. I also measured the signal coupled into the main trace from the one crossing it at 153mV, significant, but not as nearly as bad as a parallel run.

Another thing of note about a ground plane is that traces over it have a significant capacitance to ground of around .7 pF per cm for the 1mm wide traces I used. This can cause trouble for high impedance signals, even on relatively short traces. Additionally, this capacitance will only get worse the more layers the board has, especially with the common habit of placing the ground/power planes in the middle layers of the board.

The driving impedance matters a lot for capacitive coupling, when the victim trace was driven through a 100 Ω resistor instead of being left open, the coupled signal dropped to ~1/4 of the original voltage.

Inductive coupling

For inductive coupling, I alse used a 50 MHz sine, but grounded the other ends of the traces. I also added a ~10 Ohm current shut (10mV = 1mA) to measure the current flowing.

Inductive coupling test setup

Again, these measurements are only accurate to around 5%, so pay no attention to single milivolt differences.

Shunt voltage peak-to-peak (More is better)Coupled peak-to-peak voltage (More is worse)Trace configuration
8 mV62 mVNo ground plane, return path provided by scope/generator leads
12 mV26 mVStandard ground plane
11 mV28 mVStandard ground with trace cutting across the ground plane crossing the tested traces
10 mV29 mVStandard ground with trace cutting across the ground plane along the tested traces
8 mV44 mVSplit ground between traces
9 mV28 mVTraces running over split
11 mV28 mVTwo layer ground
9 mV22 mVTwo layer ground + via stitching
10 mV33 mVTwo layer ground + shield trace
10 mV7 mVTwo layer ground + shield trace + via stitching

The results here are similar to the capacitance results, and don’t contridict any of the conclusions made there. While it looks like inductive coupling is insignificant compared to capacitive coupling, it can effect traces with a very low driving impedance (like the 0 Ohm short used for testing), and the current used here was just a miliamp, not the several amps common for driving MOSFET gates and the like.

Does any of this even matter?

While 50 MHz seems quite high, this type of coupling can easly happen with digital signals. Even of the frequency of a square wave is just a few kilohertz, it can have harmonics up into the hundreds of megahertz depending on the rise time. Digital lines themselves are fairly resistant to interference because of the low impedance output and large gap between logic levels.

However, most projects at some point deal with analog signals, and these signals can easily be interfered with by fast switching digital lines. The simplest fix is to physically separate digital and sensitive analog sections, as well as avoiding parallel traces between them. Keeping the supply clean with decoupling capacitors, ferries and ground plane is also very important. High impedance lines are problematic, so avoiding them if possible and keeping them short is ideal. A via stitched shield trace over a ground plane is a good last resort.

Another statagy if coupling is unavoidable is to simply slow down the digital signals, for example by placing a 5 kOhm resistor in paralel with the output. This won’t effect low speed signaling, but will slow down problematic edges.

Another case is when the return path for current is not ground, and for that a ground plane is a lot less effective. In this case simply route the PCB so that the signal trace and return path as as close as possible, and keep the overall length short.


  1. The signal trace itself is only half of the circuit, and the return path is just as important. ↩︎

  2. This is the result I got after running a jumper to connect the 2 sides of copper fill. Without this the voltage was lower (150mV), because my scope and function generator were floating relative to each other. ↩︎